T-K3

The T-K3 model, also known as the "Revolutionary T-K3," is one of Takagi's most versatile and powerful residential units. The T-K3 offers Easy-Link capability, which allows you to connect up to four units without the use of a controller unit. The T-K3 can also be converted to a direct vent model.

Downloads:

Download T-K3 Manual

Download T-K3 Specification Sheet


There are many features that make this unit stand out from the rest:

Compact Size: Only 13.8 inches wide, the T-K3 can be recessed between wall studs for even more space savings! A special recess box is available for outdoor installations.

Lower Activating Flow Rate: The T-K3 activates at only 0.5 GPM, which allows the use of smaller water flows in bathroom sinks and showers. This reduces water waste and allows for stable temperatures.

Parallel Installation: Using Takagi's Easy Link technology, the T-K3 can be installed in parallel with up to three other units without the use of an additional control box, generating more flow while saving money, space and installation time. Four T-K3 unites will deliver a total of 21.6 GPM at 60 degrees F delta T; or 26 GPM at a 50 degree F delta T.

Direct-Vent Conversion: The T-K3 can be easily converted into a direct vent model for inside installations that need to import combustion air from outside.

Eight Temperature Settings: Instead of the usual four settings, the T-K3 offers eight separate temperatures, set by dip-switch: 104 degree F, 113 degree F, 122 degree F, 131 degree F, 140 degree F, 158 degree F, 176 degree F, and 185 degree F. This versatility reduces the need for a separate remote control. However, setting temperatures other than the eight presets requires the TM-RE10 temperature controller.

Longer vent runs: The T-K3 can have a vent pipe run up to 50 feet with five elbows, instead of the normal 35 with three elbows.

As you can see, the T-K3 incorporates all those "why-don't-you-have-this?" features into this one new product. Its larger flow capacity through parallel connections will meet the hot-water needs of most high-volume residential applications and many commercial projects, too. In short, the T-K3 fills the gap between the single residential heater and multiple commercial T-M1 units. Performance depends on the temperature of the ground water of course: At a delta T of 60 degrees F in warmer areas - for example, where the winter ground water is 60 degrees F and with the output set at 122 degrees F - the T-K3 will provide a 5.4 GPM, or 324 GPH. In colder areas where the input temperature may be 40 degrees F or less, expect a flow rate about 4.1 GPM, or 246 GPH.

Natural Gas Input Min. 11,000 Btu  Max. 199,000 Btu 
LPG Input Min. 11,000 Btu  Max. 199,000 Btu 
Gas Connection 3/4"   
Water Connection 3/4"   
Natural Gas Pressure Inlet Min 5.0" W.C.  Max 10.5" W.C. 
LP Gas Pressure Inlet 8" Min. W.C.  13.5" Max. W.C. 
Weight 40 lbs  Electronic Ignition 
Dimensions 20.5" X 13.8" X 8.5"   
Ignition Electronic Ignition   
Electrical Supply AC 120 V   
Water Pressure Min. 15 psi  Max. 150 psi 
Manifold Pressure Natural 2.5  Propane 4.4 
TM-RE30
Temperature Remote Control
The TM-RE30 Temperature Remote Controller allows the output temperature to be adjusted beyond the factory settings, and works as a diagnostic tool for error codes.
TK-TV13
Wall Ventilation Terminator for Direct Vent
The TK-TV13 Wall vent terminator is used where a tankless hot water unit will be vented through a wall.
TK-TV10
Direct Vent Conversion Kit
The TK-TV10 direct vent conversion kit can be used to convert the tankless hot water unit from a conventional vent system to a direct vent (or sealed combustion) system.
TK-TV04
Outdoor Ventilator Cap
The TK-TV04 vent cap kit is installed on the top of the unit to allow outside installation of the tankless unit.
TK-RB01
Recess Box
The TK-RB01 Recess box completely houses the tankless unit and allows the installation to be entirely recessed into a wall.  The recess box measures just over 14 inches wide to easily fit in-between studs.
TK-RB01 Spec. Sheet
TK-PC01
Pipe Cover
The TK-PC01 Pipe cover is designed to be attached directly to the bottom side of the unit to provide a cover for the pipe connection entry.
TK-KPWH4
Cap Wall Thimble With Hood
The TK-KPWH4 T-Vent wall thimble with hood termination is used when venting out through the wall and are compatible with the T-Vent pipe system.
TK-IV-01R-AB
Lead Free Isolation Valves & Pressure Relief Valve
Isolation valves are used to isolate a unit for service. The Pressure Relief Valve is to help protect the unit and release if the pressure in the tankless water heater or hot water system exceeds 150 psi. (Made for use with Recess Box) (1953 compliant)
TK-IV-01R
Isolation Valves & Pressure Relief Valve
Isolation valves are used to isolate a unit for service. The Pressure Relief Valve is to help protect the unit and release if the pressure in the tankless water heater or hot water system exceeds 150 psi. (Made for use with Recess Box)
TK-IV-01-AB
Lead free Isolation Valves & Pressure Relief Valve
Lead free Isolation valves are used to isolate a unit for service. The Pressure Relief Valve is to help protect the unit and release if the pressure in the tankless water heater or hot water system exceeds 150 psi. (1953 Compliant)
TK-IV-01
Isolation Valves & Pressure Relief Valve
Isolation valves are used to isolate a unit for service. The Pressure Relief Valve is to help protect the unit and release if the pressure in the tankless water heater or hot water system exceeds 150 psi.
TK-BF01
Exhaust Backflow Prevention Kit
The TK-BF01 prevents cold air from entering the vent and causing heat exchanger to freeze.