T-KD20
uses a "Direct Vent System". With a three-inch round combustible air intake vent and four-inch round exhaust power vent, FLASH T-KD20 is designed to work when indoor combustion air is not available - making it the perfect system for climate -controlled environments such as colder areas.
 

Technical Specifications
 
Natural Gas Input Min. 20,000 Btu Max. 185,000 Btu
LPG Input Min. 19,000 Btu Max. 175,000 Btu
Gas Connection 3/4" NPT
Water Connections 3/4" NPT
Water Pressure Min. 15 psi Max. 150 psi
Natural Gas Pressure Inlet Min. 5" WC Max. 10.5" WC
LP Gas Pressure Inlet Min. 11" WC Max. 14" WC
Manifold Pressure Natural 2.3" WC Propane 2.5" WC
Weight 60 lbs.
Dimensions 25" x 16.5" x 8.3"
Ignition Electronic Ignition
Electrical Supply AC 120 V
Specifications may change without prior notice.

Installation Manual TKD20.pdf (994 KB)
required Adobe Acrobat Reader
Specification TKD20_SideA.pdf (994 KB)
TKD20_SideB.pdf (994 KB)
required Adobe Acrobat Reader