TCT-199I-N - 199,000 BTU Commercial Natural Gas Indoor Condensing Ultra-Low NOx

TCT-199I-N

TCT-199I-N (Indoor)

The CT-199 series are High Efficiency Commercial Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to 0.95 Uniform Energy Factor (UEF) which lowers operating costs and is environmentally friendly. 


Number of showers this unit can handle, depending on ground water temperature.

Warmer Climates

Cooler Climates

Overview

  • 6-year limited Heat Exchanger Warranty, 5-year parts warranty, 1-year labor warranty for Commercial applications
  • Primary heat exchanger is constructed of a commercial grade copper that is more resilient to erosion.
  • Secondary heat exchanger is made of type 316L stainless steel to protect against corrosion.
  • Complies with SCAQMD 1146.2 Ultra-Low NOx regulations of less than 14 ng/J (<20ppm)
  • Easy-Link with up to three other CT-199 units to increase flow capacity
  • Common Vent up to 8 units
  • Condensing Indoor model
  • Safety features include Air-Fuel ratio (AFR) sensor, freeze protection, overheat cut-off fuse, exhaust & water temperature safety control, and troubleshooting diagnostic codes

Tech Specs

Emissions: Ultra-Low NOx
Maximum BTUs: 199,000
Minimum BTUs: 15,000
Water Connection Location: Bottom
Water Connection: 3/4"
Flow Rate: 10.00
Heat Exchanger: Commercial Grade Copper
Voltage: AC 120V
UEF: 0.93
ENERGY STAR® Qualified: No
LEED Rating: 1.5
Remote Control: No
Technology: Condensing
Multilink: Yes

Dimensions & Venting

Height: 23.63"
Width: 17.75"
Depth: 11.25"
Product Weight: 70 lbs.
Vent Type: Direct Vent
Vent Size: 3 or 4"

Venting

9008847005
Non-Return Valve

The 9008847005 Non-Return Valve is a must-have item for common venting system. It prevents the escape of combustion gas through non-operating appliances.


For Use with the following models:

T-H3J-IN, T-H3S-IN, T-H3-IN


9007611005
Concentric PVC Termination

The 9007611005 Concentric PVC Termination is used when terminating direct-vent (sealed combustion) systems, with Indoor models that require a 3 in. (76 mm) intake and a 3 in. (76 mm) exhaust. This concentric termination provides the convenience of only having to make one penetration through a sidewall instead of two separate penetrations for the intake and exhaust piping. The termination includes a bird screen, restricting small animals, pests, and foreign objects from entering into the vent system.


For Use with the following models:

T-H3M-IN, T-H3J-IN, T-H3S-IN, T-H3-IN 


Accessories

9008331005
Pipe Cover

The 9008331005 Pipe Cover protects the plumbing pipes to the water heater from unexpected adjustments. This pipe cover is fixed to the bottom of the water heater, which hides the plumbing and improves the visual aspects of the whole installation for the water heater.

 


For Use with the following models:

T-H3J-IN, T-H3J-OS, T-H3S-IN, T-H3S-OS, T-H3-IN, T-H3-OS


9008300005
Multiple Unit Controller

The 9008300005 Multi System Controller is capable of handling up to 20 units at one time. It also works as a diagnostic tool that provides error codes.


For Use with the following models:

T-D2U-IN, T-D2U-OS, T-H3-IN, T-H3-OS, TK-510C


9008172005
Remote Temperature Controller

The 9008172005 Temperature Remote Controller (TM-RE40) is designed for commercial tankless applications that require higher outlet temperatures. It also works as a diagnostic tool that will give a concise error code whenever there is a problem with the unit.


For Use with the following models:

T-H3-IN, T-H3-OS


9007604005
Lead Free Isolation Valves & Pressure Relief Valve

The 9007604005 Lead Free Isolation Valves & Pressure Relief Valves are used to isolate a unit for service. The Pressure Relief Valve is to help protect the unit and release if the pressure in the tankless water heater or hot water system exceeds 150 psi and up to 200,000 BTUs. For 3/4" water lines. (1953 Compliant)


For Use with the following models:

TK-110C-NI, TK-310C-NI, TK-510C-NI, T-KJr2/U, T-K4/U, T-D2/U, T-H3M, T-H3J, T-H3S, T-H3


9007607005
Neutralizer

The 9007607005 Neutralizer assembly neutralizes the condensate (acidic water) that forms in the secondary heat exchanger of the water heater. It connects to the condensate drain port of the water heater by using connectors included with the neutralizer kit.


For Use with the following models:

T-H3M-IN, T-H3M-OS, T-H3J-IN, T-H3J-OS, T-H3S-IN, T-H3S-OS, T-H3-IN, T-H3-OS 


9008847005
Non-Return Valve

The 9008847005 Non-Return Valve is a must-have item for common venting system. It prevents the escape of combustion gas through non-operating appliances.


For Use with the following models:

T-H3J-IN, T-H3S-IN, T-H3-IN


9008846005
PVC Adapter

The 9008846005 PVC Adapter for Common Venting.

 


For Use with the following models:

T-H3J-IN, T-H3S-IN, T-H3-IN


9007611005
Concentric PVC Termination

The 9007611005 Concentric PVC Termination is used when terminating direct-vent (sealed combustion) systems, with Indoor models that require a 3 in. (76 mm) intake and a 3 in. (76 mm) exhaust. This concentric termination provides the convenience of only having to make one penetration through a sidewall instead of two separate penetrations for the intake and exhaust piping. The termination includes a bird screen, restricting small animals, pests, and foreign objects from entering into the vent system.


For Use with the following models:

T-H3M-IN, T-H3J-IN, T-H3S-IN, T-H3-IN 


PP-AS20
Product Preservers® Anti-Scale System

Did you know more than 85% of American homes have hard water and that hard water scale is a leading cause of failure for tankless water heaters?

The Product Preservers® Anti-Scale System protects your tankless water heater from damage due to scale formation. This system does not add chemicals to the water or require electricity. As water flows through the filter, hard water minerals form inactive scale crystals which flow through the water heater without sticking to the heat exchanger.

The system virtually maintenance free as the filter only needs to be changed every two years. Replacing the filter is easier, faster, and needs to be less frequently than using isolation valves to flush a water heater with a cleaning solution to remove scale buildup.


Rebates

Local Energy Star Rebates

Find a distributor or service provider in your area.

Find a Dealer

Register your product online and you can benefit from our full warranty and support.

Register Your Product


Download PDF